We develop and produce for maximum resistance.

RT-Thermolight

Thermolight 1000

The RT Thermolight comprises a 20mm thick Polycarbonate multi wall sheet with side integrated corrugations placed onto custom-fitted aluminium profiles. The cover width of 1000mm makes it the ideal solution for non-airconditioned spaces with established sandwich panel roofing. Integrated ventilation windows can be installed with a recommended minimum pitch of 10°.

For pitched or curved systems

Thickness20 mm
Building width1080 mm –2/+6 mm
Up-Valueapprox. 1.6 W/m2K
Flammability classificationfire class B-s1, d0 according to EN 13501
Transmissioncrystal approx. 60 %
VersionsColor

PC 21000-30-XL

Thickness30 mm
Building width924/1,005 mm
Up-Valueapprox. 1,4 W/m2K
Flammability classificationfire class B-s1, d0 according to EN 13501
Transmissionslightly opal approx. 50 %
VersionColor

PLP 1000-30

Thickness30 mm
Building width1,000 mm
Up-Valueapprox. 1,3 W/m2K
Flammability classificationfire class B-s1, d0 according to EN 13501
Transmissionopal approx. 43 %

PC 2685-3

Our polycarbonate panel 2685-3 has a minimum thickness of 40mm and a maximum thickness of 85mm with a building width of 600mm. Panels can be interlocked to accommodate different width openings.

For pitched systems

Thickness40/85 mm
Building width600 mm –2/+6 mm
Up-Valueapprox. 1.6 W/m2K
Flammability classificationB-s1, d0 nach EN 13501
Transmissioncrystal approx. 60 %
opal approx. 43 %
VersionsColor

PLP 1000-40

Thickness40 mm
Building width1,000 mm
Up-Value (average value)approx. 1.1 W/m2K
Flammability classificationB-s1, d0 according to EN 13501